Minimum test point gas pressure, Commissioning – Rheem GAS BOOSTED SOLAR WATER HEATER User Manual

Page 49

Advertising
background image

COMMISSIONING

49

Minimum test point gas pressure
Refer to the rating label on the water heater for the minimum test point gas pressure.

1. Open a hot tap slowly until the burners ignite.

2. Press and hold down the MIN button (“1L” is shown

on the LED display), and observe the reading on
the manometer.

3. Release the MIN button. If the manometer reading

observed in Step 2 agrees with the rating label, no
further adjustment is required.

4. To adjust, press and hold down the adjuster button

(“LH” is shown on the LED display).

Note: The adjuster button must be held down
continuously through steps 4 to 6.

5. Press the MIN button and observe the reading on

the manometer.

Note: While the MIN button is pressed, the gas
pressure will at first increase then decrease,
cycling between an upper gas pressure limit (39 on
LED display) and a lower gas pressure limit (01 on
LED display).

6. Release the MIN button when the reading on the manometer agrees with the rating label.

7. Release the adjuster button.

Notes:

• If the burners extinguish and / or an error code starts to flash on the display, release the MIN and

adjuster buttons, close the hot tap, clear the error code, turn on the water heater and recommence
the procedure from Step 1.

• If the adjuster button is released before Step 6, clear any error code (if displayed) and recommence

the procedure from Step 1.

• To clear an error code, refer to

“Error Codes”

on page 16.