CONNECTIONS – ELECTRICAL

34

HOT SENSOR LEAD
House the hot sensor lead at the water heater in the flexible conduit provided and secure the conduit in
the cut out on the tab located behind the upper front cover. Connect the hot sensor cable to the hot
sensor cable connector located on the tab behind the upper front cover. Secure the hot sensor lead to
the water heater jacket to prevent possible damage.

TEMPERATURE SETTING
The preset outlet booster temperature setting of the gas booster should not be adjusted. The setting
can only be adjusted by your nearest Solahart Dealer. The preset outlet booster temperature setting is
60

°C.

AUXILIARY PUMP
The auxiliary pump, if installed, must be wired to the control board. The wiring must be housed in a
flexible conduit, which must be secured to the side of the solar storage tank. Connect the wiring to the
terminals on the auxiliary pump and to the terminals marked “2nd Pump” on the control board. Refer to

“Wiring Diagram”

on page 34 for the position of the connection.

WIRING DIAGRAM