Installation – solar collectors, Solar collector location, Latitude of some australian cities – Rheem GAS BOOSTED SOLAR WATER HEATER User Manual

Page 26: Solar collector, Location

Advertising
background image

26

INSTALLATION – SOLAR COLLECTORS

SOLAR COLLECTOR LOCATION
Consideration must be given to the position of the solar collectors in relation to the solar storage tank.
There are limitations on both the maximum length of the solar hot and solar cold pipes and the
maximum height between the solar storage tank and the solar collectors. Refer to

“Solar Storage Tank

Location”

on page 17 and to

“Pipe Lengths”

on page 27.

• The solar collectors must be installed in a shade free position.

• The solar collectors are to be installed facing toward

the equator (i.e. north facing in the southern
hemisphere and south facing in the northern
hemisphere). Where this orientation is not practical, a
system facing up to 45

° from the equator will have its

efficiency reduced by approximately 5%.

• Inclination of the solar collectors should be

approximately equal to 90% of the local latitude angle.
The

latitudes of some Australian cities

are listed on

page 26. Solar collectors may be installed at the roof
angle for simplicity of installation and appearance, but
must never be less than 10

°. If the roof angle varies

by 15

° from the correct angle, efficiency will be

reduced by 10%.

• For an installation on a roof with a pitch less than 10°,

a Variable Pitch stand is required. Refer to your local
Solar Distributor for details.

• For an installation at right angles to (across) the roof pitch, a Flat Roof stand and an Across Pitch

stand are both required. Refer to your local Solar Distributor for details.

• For an installation opposite to (against) the roof pitch, a Flat Roof stand and an Against Pitch stand

are both required. Refer to your local Solar Distributor for details.

• The collector kit is suitable for installations with an inclination of up to 45°. Where the solar

collectors are installed at inclinations greater than 45

°, a With Pitch frame is necessary. Refer to

your local Solar Distributor for details.

• The roof must be suitable to take the mass of the solar collectors. Each solar collector and its

fittings weighs approximately 45 kg when full of water.

• The installation must comply with the requirements of AS/NZS 3500.4 and all local codes and

regulatory authority requirements.

• Refer to the installation instructions supplied with the collector kit for details on the installation of

the solar collectors.

LATITUDE OF SOME AUSTRALIAN CITIES

Adelaide

35

°S

Cairns

17

°S

Hobart

42

°S

Port Hedland

20

°S

Alice Springs

24

°S

Canberra

35

°S

Mildura

34

°S

Rockhampton 24

°S

Brisbane

27

°S

Darwin

12

°S

Melbourne

38

°S

Sydney

34

°S

Broken Hill

31

°S

Geraldton

28

°S

Perth

32

°S

Townsville

19

°S

Advertising