RAD Data comm ASMi-31 User Manual

Page 18

Advertising
background image

Chapter 1. Introduction

ASMi-31

Installation and Operation Manual

1-6

Technical Specifications

16-03-00 15:51

Clock Source

Master Clock

Internal clock

– The master clock uses its own

internal crystal when transmitting or receiving
data from the DTE interface and from the line.
External clock

– The master clock uses the

clock derived from the digital interface to
receive data from the DTE and for transmitting
data to the line.
If the digital interface is X.21, the same clock is
used to transmit and receive data.

Slave Clock

Loopback timing

– The clock is recovered

from the line signal and used to transmit and
receive data from the DTE interface to the
line.

Control Signals

Jumper-selectable:

RTS to DCD

DTR to DSR

Diagnostics

Loopback Tests

Remote Digital Loopback

– REM activated by

pin in DTE interface supported by the
appropriate standard
Analog Loopback

– Local (ANA defined by

the standard as LLB) activated by pin in DTE
interface supported by the appropriate
standard

Indicators

PWR (green)

Power

RTS (yellow)

Request To Send (Circuit 105)

TD (yellow)

Transmit Data (Circuit 103)

RD (yellow)

Receive Data (Circuit 104)

DCD (yellow)

Data Carrier Detect (Circuit 109)

LOS (red)

Loss of signal

ERR (red)

Error is detected in received configuration
information

TEST (red)

A test is active

Power

AC Voltage

115 VAC or 230 VAC (10%), 5W

Frequency

50 or 60 Hz (47 to 63 Hz)

DC Voltage

-48 VDC (-36 to -72 VDC)

Power Fuses

0.1A, slow-blow for 230V