Remote loopback (rlb) – RAD Data comm ASMi-31 User Manual

Page 35

Advertising
background image

ASMi-31 Installation and Operation Manual

Chapter 4. Tests and Diagnostics

24-01-00 19:17

Diagnostic Tests

4-3

Remote Loopback
(RLB)

This test determines the performance of both the local and the remote
ASMi-31 modems, as well their connecting 2-wire line between them. The
test activates a diagnostic loopback at the remote ASMi-31 modem (see
Figure 4-2).

Local

DTE

Remote

DTE

Link

Interface

Link

Interface

Transmit

Receive

Receive

Local ASMi-31

Remote ASMi-31

Transmit

Data

Data

Clock

Clock

Figure 4-2 Remote Digital Loopback

To activate the Remote Digital Loopback:

Activate the Remote Loopback via the DTE interface.

The TEST LED lights on both units.

Set the DTE equipment in half duplex (which produces an "echo" through
the system), or run a Bit Error Rate test.
Perform the test at both ends. If the BER test indicates a fault and if the LLB
test was successful for both local and remote modems, then the 2-wire line
circuits inside the modem are not operating properly, or the line connection
between the modems is faulty.

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com