3.2.3. Power Supply Wiring And Grounding

The RSG2300 supports a single AC or DC power supply, PS1, and a separate 48VDC power
supply, PS2, which provides power to the PoE ports.

The connections for PS1, PS2 and the fail-safe relay are located on the terminal block as shown
in

Figure 3.12, “RS2000 Series Phillips Screw Terminal Block”

and

Figure 3.13, “RS2000 Series

Phoenix Plug Terminal Block”

.

The RSG2300 can be equipped with either a Phillips Screw Terminal Block or a Phoenix Pluggable
Terminal Block. The Phillips Screw Terminal Block has Phillips screws with compression plates,
allowing either bare wire connections or crimped terminal lugs. We recommend the use of #6 size
ring lugs to ensure secure, reliable connections under severe shock or vibration. Both terminal
blocks have a safety cover which must be removed via two Phillips screws before connecting
any wires. The safety cover must be re-attached after wiring to ensure personnel safety. Refer
to

Table 3.1, “RSG2300 Power Terminal Block Connection Description”

for a description of each

terminal. Refer to

Section 3.2.3.1, “AC Power Supply Wiring Examples RSG2300”

,

Section 3.2.3.2,

“DC Power Supply Wiring Examples RSG2300 and RSG2300P”

and

Section 3.2.3.3, “AC and DC

Power Supply Wiring Example RSG2300 and RSG2300P”

for power supply wiring examples.