3.2.3.2. DC Power Supply Wiring Examples RSG2300 and RSG2300P

+

Figure 3.17. DC Single Power Supply Wiring Example

+

+

Figure 3.18. DC Dual Redundant

Power Supply Wiring Example

• RSG2300P will always have a 48VDC power supply in position PS2.

• 125/250VDC rated equipment: A 300VDC appropriately rated circuit breaker must

be installed.

• A circuit breaker is not required for 12-24 or 48 VDC rated power supplies.

• For dual DC power supplies, separate circuit breakers must be installed and

separately identified.

• Equipment must be installed according to the applicable country wiring codes.

3.2.3.3. AC and DC Power Supply Wiring Example RSG2300 and RSG2300P

+

Figure 3.19. AC and DC Power Supply Wiring Example