5. EMI And Environmental Type Tests

RuggedCom® RuggedSwitch®

34

RSG2300 Installation Guide Rev 110

Test

Description

Test Levels

Enclosure Contact

+/- 8kV

IEEE C37.90.3

ESD

Enclosure Air

+/- 15kV

IEEE C37.90.2

Radiated RFI

Enclosure ports

35 V/m

Signal ports

+/- 4kV @ 2.5kHz

D.C. Power ports

+/- 4kV

A.C. Power ports

+/- 4kV

IEEE C37.90.1

Fast Transient

Earth ground ports

a

+/- 4kV

Signal ports

2.5kV common mode @1MHz

D.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

IEEE C37.90.1

Oscillatory

A.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

Signal ports

5kV (Fail-Safe Relay output)

D.C. Power ports

5kV

IEEE C37.90

H.V. Impulse

A.C. Power ports

5kV

Signal ports

2kVAC

D.C. Power ports

1.5kVDC

IEEE C37.90

Dielectric Strength

A.C. Power ports

2kVAC

Table 5.2. IEEE 1613 (C37.90.x) EMI Immunity Type Tests

Test

Description

Test Levels

Severity Levels

IEC 60068-2-1

Cold Temperature

Test Ad

-40°C, 16 Hours

N/A

IEC 60068-2-2

Dry Heat

Test Bd

+85°C, 16 Hours

N/A

IEC 60068-2-30

Humidity (Damp

Heat, Cyclic)

Test Db

95% (non-condensing), 55°C , 6 cycles

N/A

IEC 60255-21-1

Vibration

2g @ (10 - 150) Hz

Class 2

a

IEC 60255-21-2

Shock

30g @ 11mS

Class 2

a

a

Class 2 refers to “Measuring relays and protection equipment for which a very high security margin is required or where

the vibration levels are very high, e.g. for shipboard applications and for severe transportation conditions.”

Table 5.3. Environmental Type Tests