Installation – Regency IG34-LPG User Manual

Page 12

Advertising
background image

12

Regency IG34 Gas Inbuilt Fireplace

Conversion Kit #486-967 for NG to ULPG

INSTALLATION

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

C

onversion Kit 486-967 Contains:

Qty. Part # Description
1 904-345 Burner Orifi ce #53
1 918-273 Red "ULPG" label
1 918-272 Label "Converted to ULPG"
1 910-037 LPG Pilot Injector
1 918-824 Instruction Sheet

1) Shut off the gas supply and unplug

the power cord.

2) Remove the glass door, logs and

lava rock.

3) Remove the rear log tray by remov-

ing the 2 screws. (Log tray must be
rotated to clear the burner.)

4) Remove the grate.

5) Remove the burner and ensure the

aeration setting is 13 mm open.

6) Remove burner orifi ce with a 1/2"

wrench and discard. Use a wrench
to hold on to the elbow behind the
orifi ce.

Control Box

Cover

Antenna

Jumper Location

16) Remove the jumper using a plier.

7) Reinstall new burner orifi ce ULPG

stamped #53 and tighten.

8) Apply the conversion label "This

unit has been converted to ULPG"
over top of the serial number decal.

12) Replace the yellow "NG" label with

the red "ULPG" label.

13) Carefully pull out the control box.

NOTE: The control box is held in
place with velcro.

14) Remove the heat shield from the

control box by removing the 2

screws.

15) Remove the control box cover by

undoing the 3 screws.

Maneuver through an

tenna.

17) Reverse steps 13, 12, 11, 6, 5, 4, 3

& 2.

Note: Aeration settings do not need

to be adjusted.

Burner

9) Pull out the pilot hood by hand.

Pilot

Hood

11) Put in the new LPG orifi ce with the

allen key. Then put back the pilot
hood.

Pilot

Hood

removed

10) Remove the pilot orifi ce with the

allen key.

Pilot

Orifi ce

Jumper

Advertising
This manual is related to the following products: