Regency IG34 Gas Inbuilt Fireplace

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes:

1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label) at 15 minutes.

2) If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3) Check for proper draft.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the

responsibility of the manufacturer.

WIRING

Caution: Ensure that the wires do not
touch any hot surfaces and are away
from sharp edges.

STANDARD WIRING

This unit is polarity sensitive and will
not operate if polarity is incorrect.

INSTALLATION

CAUTION: Label all wires prior to disconnection

when servicing controls. Wiring errors can
cause improper and dangerous operation.