Installation, Clearances to combustibles, Gas connection – Regency IG34-LPG User Manual

Page 6: Flueing, Minimum fireplace dimensions

Advertising
background image

6

Regency IG34 Gas Inbuilt Fireplace

INSTALLATION

Mantel Clearances

Note: A non-combustible mantel may be

installed at a lower height if the fram-
ing is made of metal studs covered
with a non-combustible board.

CLEARANCES TO

COMBUSTIBLES

Minimum Clearances to Combustibles

From Unit
Sides

A

10" / 255mm

Ceiling

B

47.5" / 1205mm

Mantel

C 13" / 330mm

Max. Mantle Depth

E

12" / 305mm

(see Dia. 2)

Min. Alcove Width

F

48" / 1220 mm

Max. Alcove Depth

G

36" / 915 mm

*No hearth required.

GAS CONNECTION

GAS CONNECTION WARNING:

Only persons licensed to work

with gas piping may make the

necessary gas connections

to this appliance.

1) If the appliance is to be installed into an

existing chimney system, thoroughly clean
the masonry fi replace.

2) The appliance is provided with an opening

on the right hand side of the control
compartment. The 9.5mm (3/8") fl exible
gas hose provided needs to be brought in
from behind this opening. Ensure all gas
connections are tight.

3) Locate the center point where the vent

will pass through the chimney above the
appliance. Move the appliance into the
exact location where it is to be installed.
Ensure that the Insert is level.

CL

Gas
Inlet

FLUEING

This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. The fl ue length
must be a minimum length of 8 ' (2.44m) and
a maximum of 35' (10.7m). See chart below for
minimum distances from roof. Periodically check
that the vent is unrestricted.

Masonry chimneys may take various contours
which the fl exible liner will accommodate.
However, keep the fl exible liner as straight as
possible
, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet
air collar of the termination cap.

Part #

Description

948-305

76mm Flex - 10.6m

46dva-gk Simpson

Duravent

Adaptor

46dva-vch Simpson Vertical high wind cap

MINIMUM FIREPLACE

DIMENSIONS

The minimum fi replace dimensions for the
Regency gas space heater are shown in the
following diagrams:

THE APPLIANCE MUST NOT

BE CONNECTED TO A

CHIMNEY FLUE SERVING A

SEPARATE SOLID FUEL

BURNING APPLIANCE AND

MUST BE TERMINATED TO

THE OUTDOORS.

Note: When installing the fl ueing, identify

the fl ues.

Mark one exhaust and one intake as

indicated on the top of the unit.