Installation, Installation in masonry or zero clearance chimney – Regency IG34-LPG User Manual

Page 8

Advertising
background image

8

Regency IG34 Gas Inbuilt Fireplace

INSTALLATION

INSTALLATION IN MASONRY OR ZERO CLEARANCE CHIMNEY

1) Measure and record dimensions to determine total
Flex Liner length requirements (see instructions below
for details).

2) Carefully feed the liner down the chimney (masonry
or zero clearance) and out through the damper. One
person should feed the liner through the chimney, and
another person should pull the liner from the bottom.

3) After carefully feeding the Flex Liner down the chim-
ney to the bottom, form and angle to line up the Flex
Liner with the vent opening on the appliance.
Important: Do not let the Flex Liner sag below the level
at which it will connect to the appliance or connector.
This could allow hot gas to become trapped and poten-
tially become a fi re hazard. The Flex Liner path should
always be sloped up toward the Termination Cap.

4) Temporarily secure the Flex Liner at the top of the
chimney. Be sure to leave 2-3 inches of fl ex above the
existing chimney to allow for connection to the Termina-
tion Kit (Baseplate and Adaptor).

5) Repeat Steps 1-4 for second length of Flex Liner.

6) At the top of the chimney, slide the Baseplate over
the tow ends of the Flex Liner and secure it to the sur-
rounding masonry using masonry anchor bolts. Before
installing the baseplate, run a bead of non-hardening
seal and between the Baseplate and the masonry to
prevent moisture from entering the chimney.
Note: Verify that there is suffi cient room to mount the
Baseplate on to the masonry. You must have a level
surface in order to install the Baseplate properly.

7) Attach the Flex Liner ends at the top of the chimney
to the Co-Linear to Co-Axial Adaptor. Use four sheet
metal screws to connect each Flex Liner run to the
Adaptor.

8) Twist lock the Vertical Termination Cap to the Adap-
tor.

Note: If you are planning to extend the height of the
chimney using Direct Vent GS Pipe, please refer to the
Direct Vent Installation Instructions for information con-
cerning the proper procedure and restrictions of Direct
Vent Pipe.
Also, consult the appliance manufacturer for any height
restrictions of the chimney.

9) Connect the Co-Linear Flex to the two outlets on the
top of the appliance using four sheet metal screws each.
See the appliance manufacturer's instructions for de-
tails. Make sure the Flex Liners do not sag behind the
appliance. Finally, move the appliance into its appropri-
ate place. Mount the Adaptor to the Baseplate using
sheet metal screws.

51-76mm

Flex
Liners

Existing
Chimney

Advertising
This manual is related to the following products: