Roberts Gorden UHD[X][S][R] 150 User Manual

Page 19

Advertising
background image

SECTION 6: V

ENTING

13

Figure 7: Separated Combustion Heater - Vertical and Horizontal Vent Termination

Figure 8: Concentric Vent Box

Vent
Termination

12" (31 cm)
Minimum from
air inlet to vent
termination (may be
horizontal or vertical
clearance).

Air Intake
Termination

Vent

Air Intake*

Vertical

Option

Horizontal

Option

90°
Bend

12" (31 cm)
Minimum from wall
to vent termination.

12" (31 cm) Minimum from air inlet to

vent termination (may be horizontal

or vertical clearance).

Listed Thimble

through Combustible

Wall

Vent

Air Intake

Condensate

Trap to Drain

(Optional)

NOTE: Vent supports not
shown. Duct supports
not

shown. Duct and

vent supports not

provided by the
manufacturer.

12" (31 cm)
Minimum from
wall to vent
termination.

Model

Vent Diameter

Terminal P/N

UHD[X]S[R] 150 - 400

4" (10 cm)

90502102

Model

*Air Intake Diameter

Terminal P/N

UHD[X]S[R] 150 - 250

4" (10 cm)

90502102

UHD[X]S[R] 300 - 400

5" (13 cm)

90502105

4" (10 cm) Single
Wall Vent Pipe
(By Others)

Seal joint between single wall
and Type B vent with
silicone sealant.

Use 3 sheetmetal
screws equally
spaced around joint.

Use 3 sheetmetal
screws equally
spaced around collar.

Concentric
Vent Box

6" (15 cm) Single
Wall Inlet Air Pipe
(By Others)

One piece of 4" (1

0 cm) dia, 1/4" (6 cm)

airspace t

ype “B”

vent.

Selkir

k Model R

V

or equ

ivalent.

(By other

s)

Combustion Air
to Heater

Toward
Outside

Exhaust
from Heater

4" (10 cm) or
5" (13 cm)