Figure 3-18 . image alignment controls, 18. image alignment controls, Pre l iminar y – Runco LIGHTSTYLE LS-10D User Manual

Page 58

Advertising
background image

Installation

42

Runco LS-10d Installation/Operation Manual

PRE

L

IMINAR

Y

“Keystoning” usually occurs when the projector is tilted relative to the screen. “Pincushion”
distortion can sometimes occur if the throw distance is very short and/or the projector is
equipped with an anamorphic lens.

To correct keystoning or pincushion distortion:

1.

On the DHD Controller remote control or front panel, press MENU.

2.

Select Calibration from the Main Menu and enter the Calibration Menu passcode.

3.

Select Image Alignment from the Calibration Menu.

4.

Select Corner Alignment to correct a “keystoned” image by adjusting the image
corner positions. Select Midpoint Alignment to correct pincushion distortion by
adjusting the image edge mid-points. See Figure 3-18.

Figure 3-18. Image Alignment Controls

You must enter a passcode to access the Calibration menu.

The “Left Middle y” setting also controls the “Right Middle”
y-coordinate. Similarly, the “Top Middle x” setting also controls the
“Bottom Middle” x-coordinate.

Note

Top Left (x, y)

Left

Middle

(x, y)

Right
Middle
(x)

Bottom Left (x, y)

Top Right (x, y)

Bottom Right (x, y)

Top Middle (x, y)

Bottom Middle (y)

Notes:
1. Bottom Middle x = Top Middle x
2. Right Middle y = Left Middle y
3. Smaller “x” values move a point to the left; larger values move it to the right.
4. Smaller “y” values move a point up; larger values move it down.

Center

(x, y)