Clear interrupt, The analog input selection register, 6 clear interrupt – Omega 1002 User Manual

Page 32: 7 the analog input selection register

Advertising
background image

3.2.2.6 Clear Interrupt

Reading from 1Ch will clear the add-on interrupt.

3.2.2.7 The Analog Input Selection Register

The analog input channel selection register uses address 10h and

address 14h is used by the analog gain control selection register. Write 0-31 to
port 10h to select the channel number (for differential input, write 0-15).
Write 0-3 to port 14h to select the gain control.








Figure 3-2. Analog input control.


Note:

1. For single ended inputs, channels 0-31 are available. For

differential inputs, channels 0-15 are available. If you enter a
channel number greater than the number available, those channels
will be ignored. Thus, for single-ended inputs, only the last 5 bits
are taken as the channel number. And for differential inputs, only
the last 4 bits are taken as the channel number.


2. Only the last two digits are used as the gain control code. The gain

control codes and corresponding gains are shown below :


For OME-PCI-1002L:

Gain code

[0 0]

[0 1]

[1 0]

[1 1]

Gain 1

2

4 8

Analog inputs

Channel select

Analog

Mux.

Select

Gain control

ADC

AMP

32