The general control register, Interrupt source selection, 8 the general control register – Omega 1002 User Manual

Page 33: 1 interrupt source selection

Advertising
background image


For OME-PCI-1002H:

[Bit1,Bit0]

[0 0]

[0 1]

[1 0]

[1 1]

Gain 1 10 100

1000

3. These registers are set to 0 after power-on or a hardware reset signal.



3.2.2.8 The General Control Register


The general control register (18h) is used to control the add-on interrupt

source and the A/D trigger method. The format of this register is:

Bit4-2 Bit

1-0

Interrupt source

selection register

A/D trigger method

selection register

3.2.2.8.1 Interrupt Source Selection

There are four interrupt sources selectable for the OME-PCI-1002 (see

section 1.4.4).

[Bit4,Bit3,Bit2] Description

[ 0, 0, 0 ]

No interrupt source, disable all interrupts.

[ 0, 0, 1 ]

Interrupt after A/D conversion completes.

[ 0, 1, 0 ]

Interrupt after 8254 timer 0 falling.

[ 0, 1, 1 ]

Interrupt after external trigger falling.

[ 1, 0, 0 ]

Interrupt after 8254 timer 1 falling.

Others

No interrupt source, disable all interrupts.

Note: Bit 3-3 of general control register is set to 0 after a hardware reset.



33