Orion LBI-38888K User Manual

Page 50

Advertising
background image

50

Exiting Data Calls

Under normal conditions, the radio enters the scan lockout mode and
returns to the control channel after completion of a data call (transmit or
receive). If, during a data call, one of the following conditions occurs, the
data call is immediately terminated and the radio performs the desired
function:

PTT activated.

PTT in Public Address mode.

Emergency declared by pressing the pre-programmed emergency
button.

A group or system change.

Scan Lockout Mode

Following the transmission or reception of a data call, if scan is enabled,
scanning will stop temporarily (duration pre-programmed). During this time
the scan LED will flash to indicate that scan is enabled but temporarily
suspended. This mode is normally exited when the pre-programmed time
expires; however, the following actions will terminate the scan lockout
mode before the timeout is completed.

The

c

(System Model) or

C

(Scan Model) button is pressed.

PTT is pressed.

A group or system change.

Entering phone call mode

Entering individual call mode.

A new emergency assignment has been received.

PTT pressed in Public Address Mode.

An emergency declared or cleared.

Microphone removed from hookswitch (OFF-hook).

Receiving an individual or phone call.

Receiving Agency, Fleet or System All Call.

Pressing the

k

button to turn scan ON or OFF.

Advertising