Chapter 3 Maintenance & Disassembly


3.2.19 Platen Assembly

1. Perform these procedures:

3.2.01

, and 3.2.06

.

2. Move the change lever (1) to the bottom feed position (to the rear of the printer).

3. Push the lock levers (2) in, then rotate them towards the front to unlock them from the frame.

4. The levers should be vertical.

5. Lift the platen assembly (3) straight up and remove it.

NOTE:

Installation

After installing the platen assembly, check the printhead gap adjustment. Refer to Section 3.3 of
this Service Handbook.

Cleaning

When cleaning, refer to Section 3.4 of this Service Handbook.

Lubrication

When lubricating, refer to Section 3.5 of this Service Handbook.