Oki ML520 User Manual

Page 188

Advertising
background image

8

Printhead
Connection Alarm
(2)

Self adjust was not
successful. Head gap is
too small or too narrow.

Check the printhead
connection. Then
replace the main control
board the carriage cable
and the printhead.

9

Line Feed / Space
Motor Driver Alarm

High driver temperature.
The TSD signal has not
changed.

Replace the following:
main control board line
feed motor and space
motor.

10

MPU Internal RAM
Alarm

Read/write error

Replace the main control
board.

11

Program ROM
Alarm

Check sum error

Replace the main control
board and/or ROM.

12

RAM on Main
Control Board

Read/write error

Replace the main control
board.

13

CG ROM Alarm

Check sum error

Replace the main control
board.

CAUTION:

Always check that all connectors on the printer are making good contact.