Page: 91

Service Guide ML520/521

Chapter 3 Maintenance & Disassembly


3.2.22 Reset Spring

CAUTION:

Please read through this entire procedure before performing it.

Do not press against the vertical extensions of the reset spring at any time during this procedure.

Firm pressure will release the spring, not brute force.

1. Perform these procedures:

3.2.01

, 3.2.06

, and 3.2.17

.

2. Place the right side of the unit over the edge of your work surface. You must be able to access the

bottom of the unit. You will be working underneath and above the reset spring (1) at the same time.

3. Reach from underneath the unit and press up at the extension (A) to free the spring from the claw.

4. While pressing up, slide the spring out (in the direction of Arrow B) and remove it.

P/N 50923201 Spring: Reset RSPL Both B.2.05

Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)