Main Circuit Terminals

Main circuit terminal functions are summarized according to terminal symbols in

Table 1

. Wire the

terminals correctly for the desired purposes.

Table 1 Main Circuit Terminal Functions (200 V Class and 400 V Class)

„

Control Circuit Terminals

Fig 5

shows the control terminal arrangement. The functions of the control circuit terminals are

shown in

Table 2

. Use the appropriate terminals for the correct purposes.

Fig 5 Control terminal arrangement

Table 2 Control Circuit Terminals with default settings

Purpose

Terminal Symbol

Model: CIMR-F7Z

††††

200 V Class

400 V Class

Main circuit power input

R/L1, S/L2, T/L3

20P4 to 2110

40P4 to 4300

R1/L11, S1/L21, T1/L31

2022 to 2110

4022 to 4300

Inverter outputs

U/T1, V/T2, W/T3

20P4 to 2110

40P4 to 4300

DC bus terminals

1,

20P4 to 2110

40P4 to 4300

Braking Resistor Unit Connec-
tion

B1, B2

20P4 to 2018

40P4 to 4018

DC reactor connection

1, 2

20P4 to 2018

40P4 to 4018

Braking Unit connection

3,

2022 to 2110

4022 to 4300

Ground

20P4 to 2110

40P4 to 4300

Type

No.

Signal Name

Function

Signal Level

Digital input sig

nals

S1

Forward run/stop command

Forward run when ON; stopped when
OFF.

24 VDC, 8 mA
Photocoupler isolation

S2

Reverse run/stop command

Reverse run when ON; stopped when
OFF.

S3

External fault input

*1

Fault when ON.

Functions are
selected by set-
ting H1-01 to
H1-05.

S4

Fault reset

*1

Reset when ON

S5

Multi-step speed reference 1

*1

(Master/auxiliary switch)

Auxiliary frequency ref-
erence when ON.

S6

Multi-step speed reference 2

*1

Multi-step speed 2
when ON.

S7

Jog frequency reference

*1

Jog frequency when
ON.

SC

Digital input common

SN

Digital Input Neutral

SP

Digital Input Power Supply

+24VDC power supply for digital inputs

24 VDC, 250 mA max.

*2

A

n

alog input signals

+V

15 V power output

15 V power supply for analog references

15 V (Max. curr.: 20mA)

A1

Frequency reference

0 to +10 V/100%

-10 to +10 V (20 k

Ω)

0 to +10 V (20 k

Ω

)

A2

Auxiliary Frequency Refer-
ence

Auxiliary analog fre-
quency reference;
4 to 20 mA (250

Ω)

Function is
selected by set-
ting H3-09.

4 to 20 mA (250

Ω

)

0 V to +10 V (20 k

Ω

)

0 to 20 mA (250

Ω

)

-V

-15 V power output

-15 V power supply for analog references

AC

Analog reference common

E(G)

Shield wire, optional ground
line connection point