En-10 – Omron Healthcare VARISPEEDF7 User Manual

Page 11

Advertising
background image

EN-10

Fig 6 Flywheel Diode Connection

Digital o

u

tput signals

M1

During run (NO)

Closed during Run

Function
selected by H2-
01 to H2-03

Relay contacts
Contact capacity:
1 A max. at 250 VAC

1 A max. at 30 VDC

*3

M2

M3

Zero speed (NO)

Closed when output
frequency at zero level
(b2-01) or below

M4

M5

Speed agreement detection
(NO)

Within ± 2 Hz of set fre-
quency when ON

M6

MA

Fault output signal

Closed across MA and MC during faults
Open across MB and MC during faults

MB

MC

Ana

log ou

tput signals

FM

Output frequency

Analog output fre-
quency signal;
0 to 10 V; 10V=FMAX

Function
selected by
H4-01

0 to +10 V max. ±5%
2 mA max.

-10 to +10 V max. ±5%
2 mA max

4 to 20 mA

AC

Analog common

AM

Inverter output power

Analog output power
signal;
0 to 10V; 10V=max.
appl. motor capacity

Function
selected by
H4-04

Pulse I/O

RP

Pulse Input

H6-01 (Frequency reference input)

*4

0 to 32 kHz (3k

Ω

)

High level voltage 3.5 to
13.2 V

MP

Pulse Output

H6-06 (Output frequency)

0 to 32 kHz
+15 V output (2.2k

Ω

)

RS-485/42

2

R+

MEMOBUS communications
input

For 2-wire RS-485, short R+ and S+
as well as R- and S-.

Differential input,
PHC isolation

R-

S+

MEMOBUS communications
output

Differential input,
PHC isolation

S-

IG

Signal common

*1. The default settings are given for terminals S3 to S7. For a 3-wire sequence, the default settings are a 3-wire sequence for S5, multi-
step speed setting
1 for S6 and multi-step speed setting 2 for S7.
*2. Do not use this power supply for supplying any external equipment.
*3. When driving a reactive load, such as a relay coil with DC power supply, always insert a flywheel diode as shown in

Fig 6

*4. Pulse input specifications are given in the following table:

Low level voltage

0.0 to 0.8 V

High level voltage

3.5 to 13.2 V

H duty

30% to 70%

Pulse frequency

0 to 32 kHz

IMPORTANT

1. In

Fig 4

the wiring of the digital inputs S1 to S7 is shown for the connection of contacts or NPN transis-

tors (0V common and sinking mode). This is the default setting.
For the connection of PNP transistors or for using a 24V external power supply, refer to

Table 3

.

2. A DC reactor is an option only for Inverters of 18.5 kW or less. Remove the short circuit bar when con-

necting a DC reactor.

Type

No.

Signal Name

Function

Signal Level

External power:
30 VDC max.

Coil

Flywheel diode

1 A max.

The rating of the flywheel diode must
be at least as high as the circuit volt-
age.