FC-21 Flow Computer

7.3 Flow Equations: (Continued)

Flow Equations

Input Viscosity Computation:

Uncompensated Flow Computation:

Pulse Input; Average K-Factor

input frequency * time scale factor

Volume Flow =

K-Factor

Pulse Input; Linear Table

input frequency * time scale factor

Volume Flow =

K-Factor (Hz)

Pulse Input; UVC

input frequency * time scale factor

Volume Flow =

K-Factor (Hz/cstk)

Analog Input; Linear

Volume Flow = input flow

Analog Input; Linear Table

Volume Flow = input flow * correction factor (input flow)

Analog Input; Orifice or External SQRT

√(calibrated density)

Volume Flow = input flow *

√(density)

Analog Input; Orifice Linear Table or External SQRT Linear Table

√(calibrated density)

Volume Flow = CF(rn) * input flow *

√(density)

Corrected Volume Flow Computation:

Temperature Transmitter

Standard Volume Flow = volume flow * (1 - Therm.Exp.Coef. *(Tf-Tref))

2

Density Transmitter

density

Standard Volume Flow = volume flow *

reference density

Mass Flow Computation:

Mass Flow = volume flow * density

† These special flow equations are not available in the standard unit. They are to be

offered to OEMs or as special order items.

A exp

B

(Deg F + 459.67)

Absolute Density

(

)

† centistokes =

Where: centistokes = cP/(kg/l)