Flue restrictor instructions, Straight up, Adjustable flue restrictor (see figure 8) – Quadra-Fire QV36DC-A User Manual

Page 12

Advertising
background image

Quadra-Fire • QV36DC-A • 2161-900 Rev. C • 6/09

15

Figure 6.

Straight Up Vertical Venting

STRAIGHT UP

VERTICAL VENTING

V (FT.)

40’ MAX. (12.4 M)

Flue Restrictor Instructions

1. Remove screws with a 1/4 nut driver. Adjust to

desired position per table. See Flue Restricting
chart.

NOTE: On vertical vent-
ing confi gurations over
20 feet install the fl ue re-
strictor (2027-102). See
fl ue restrictor installation
instructions.

CAP

V

Figure 7.

Figure 8

ADJUSTABLE FLUE
RESTRICTORS (2)

Adjustable Flue Restrictor (see Figure 8).

5
4
3
2
1

1
2
3
4
5

- CHART -

Vertical

Top Vent

NG

Top Vent

LP

Rear Vent

NG

Rear Vent

LP

4’

2-2

2-3

No

Restrictor

No

Restrictor

8’

3-3

2-3

2-2

No

Restrictor

15’

3-4

3-4

3-3

2-3

20’

4-4

3-4

3-4

3-4

25’

4-4

3-4

3-4

3-4

30’

4-4

4-4

4-4

3-4

35’

4-4

4-4

4-4

3-4

40’

4-5

4-4

4-4

4-4