C. vent termination – Quadra-Fire QV36DC-A User Manual

Page 21

Advertising
background image

Quadra-Fire • QV36DC-A • 2161-900 Rev. C • 6/09

24

For Vertical Runs - One ceiling fi restop is REQUIRED at
the hole in each ceiling through which the vent passes.

To install fi restops for vertical runs that pass through
ceilings:

• Position a plumb bob directly over the center of the verti-

cal vent component.

• Mark the ceiling to establish the centerpoint of the

vent.

• Drill a hole or drive a nail through this centerpoint.

• Check the fl oor above for any obstructions, such as wir-

ing or plumbing runs.

• Reposition the fi replace and vent system, if necessary,

to accommodate the ceiling joists and/or obstructions.

• Cut an 10-inch X 10-inch (254mm X 254mm) hole through

the ceiling, using the centerpoint previously marked.

• Frame the hole with framing lumber the same size as

the ceiling joists.

Figure 26. Ceiling Firestop (Ceiling Side)

If the area above the ceiling is NOT an attic, position
and secure the ceiling fi restop on the ceiling side of the
previously cut and framed hole.

If the area above the ceiling IS an attic, position and secure
the fi restop on top of the previously framed hole.

NOTE: Keep insulation away from the vent pipe at least
1 inch (25mm).

Figure 27. Attic Firestop

JOIST

CEILING FIRESTOP

CEILING

NAILS (4 REQUIRED)

CEILING

CEILING FIRESTOP

RAFTER

NAILS (4 REQUIRED)

NOTE: There must be NO INSULATION or other
combustibles inside the framed fi restop opening.

Figure 25. 10” x 10” Hole & New Framing Members

CEILING

NEW
FRAMING
MEMBERS

EXISTING CEILING
JOISTS

CHIMNEY

HOLE

10" (254mm)

)

m

m

4

5

2

(

"

0

1

!

C. Vent Termination

Refer to Cinch Pipe and Termination Cap installation in-
structions.

Horizontal Termination

• The termination kit should pass through the wall fi restops

from the exterior of the building and interlock the fl ue
sections.

• Adjust the termination cap to its fi nal exterior position

on the building and interlock the fl ue sections.

!

WARNING: VENTING TERMINALS

SHALL NOT BE RECESSED INTO A WALL

OR SIDING. VENT TERMINATION CLEARANCES
MUST BE FOLLOWED TO AVOID FIRE DANGER.
SEE VENT TERMINATION MINIMUM CLEARANCES
DIAGRAM ON FOLLOWING PAGE.

WARNING: THE TERMINATION CAP MUST BE PO-
SITIONED SO THAT THE ARROW IS POINTING UP.

Figure 28.
Trapezoid Termination Cap

7 1/4”

(184mm)