Step 8. wiring the fireplace – Quadra-Fire QV36DC-A User Manual

Page 26

Advertising
background image

Quadra-Fire • QV36DC-A • 2161-900 Rev. C • 6/09

29

Optional Accessories

Optional fan and remote control kits require that 110-120
VAC be wired to the factory installed junction box before
the fi replace is permanently installed.

Wall Switch

Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the fi replace ON/
OFF switch pigtails

BLACK S2

ON

OFF

ON/OFF

SWITCH

WHITE T2

RED T1

THERMOPILE

GAS VALVE

BLACK S1

3/16” PIGGYBACK CONNECTOR

THERMOCOUPLE

REMOTE SWITCH

PIGTAIL

OPTIONAL WALL SWITCH,

THERMOSTAT OR REMOTE

NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105

°

C RATED WIRE.

JUNCTION BOX

VARIABLE SPEED CONTROL

TEMPERATURE

SENSOR SWITCH

WHT

GRN

BLK

BLK

110-120 VAC

BLOWER

BLOWER RECEPTACLE

BLK

BLK

BLK

BLK

WHT

GROUND

WHT

BLK

BLK

BLK

BLOWER

SENSOR

SWITCH

“FAN”

RECEPTACLE

SPEED

CONTROL

Step 8. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed
electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF
ABSENT FOR EXTENDED TIME PERIODS. THIS WILL
PREVENT ACCIDENTAL FIREPLACE OPERATION.

Appliance Requirements

This appliance DOES NOT require 110-120 VAC to

operate.

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in compli-
ance with the applicable electrical codes, when it is in-

stalled in locations such as in bathrooms or near sinks.

!

Figure 34. Standing Pilot Ignition Wiring Diagram

!

WARNING: DO NOT CONNECT 110-120
VAC TO THE GAS CONTROL VALVE OR
THE APPLIANCE WILL MALFUNCTION
AND THE VALVE WILL BE DESTROYED
.

WARNING: DO NOT CONNECT 110-120
VAC TO THE WALL SWITCH OR THE CON-
TROL VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.

Advertising