Step 2. framing the fireplace – Quadra-Fire QV36DC-A User Manual

Page 9

Advertising
background image

Quadra-Fire • QV36DC-A • 2161-900 Rev. C • 6/09

12

Framing should be
constructed of 2 X 4
lumber or heavier.

S h o w s
center of 10” x
12” vent framing
holes for top and rear
venting. The center of the
hole is one (1) inch (25.4mm)
above the center of the horizontal
vent pipe.

Noncombustible zone is defined
by 3” above the elbow for the
entire width and depth (behind
the front header) of the firebox.

E

D

1/2” CLEARANCE FROM BACK OF FIREPLACE TO COMBUSTIBLE

0” CLEARANCE TO

FRAMING MEMBER

0” CLEARANCE

1/2” CLEARANCE

FROM BOTH SIDES

OF FIREPLACE

TO COMBUSTIBLE

FRAMING

MEMBER

WALL

STUD

3 1/2”

3

A. .............. 42”*

B. ..........38 1/2”

C. ................22”

D. ..........42 3/4”

E. ..........27 7/8”

A

B

C

Fireplace framing can be built before or after the fi replace is
set in place. Framing should be positioned to accommodate
wall coverings and fi replace facing material. The diagram
below shows framing reference dimensions.

Step 2. Framing the Fireplace

CAUTION: MEASURE FIREPLACE DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVERING
DETAILS BEFORE FRAMING.