7. Instructions

FUN 160

UL

Upper limit

Expression

Input

[ A UL B

C ]

Output

Function

When the input is ON, the following operation is executed. (Upper limit for A by B)
If A

B, then C = A.

If A

>

B, then C = B.

Execution condition

Input

Operation

Output

OFF

No operation

OFF

ON

Execution: not limited (A

B)

OFF

Execution: limited (A

>

B)

ON

Operand

Name

Device

Register

Constant Index

X

Y

R

S

T.

C. XW YW RW SW T

C

D

I

J

K

A Operation data

B Upper limit

C Destination

Example

When R030 is ON, the upper limit operation is executed for the data of RW018 by the data of
D1200, and the result is stored in RW021.

When RW018 is 3000 and D1200 is 4000, 3000 is stored in RW021 and R0040 is OFF.
When RW018 is 4500 and D1200 is 4000, the limit value 4000 is stored in RW021 and R0040
is ON.

Note

This instruction deals with the data as signed integer (-32768 to 32767).

C

(RW021)

Upper limit B (D1200)

A (RW018)