Volatile mode (optional), Initializing luns, Via web interface – Texas Memory Systems 325 User Manual

Page 87: Via text management, 10 initializing luns

Advertising
background image

Volatile mode (optional)

This operational mode disables the backup functionality for the LUN

making it completely volatile. In the case of system shutdown or
failure, all data stored in the selected LUN will be lost intentionally.

6.10 Initializing LUNs

The RamSan-320/325 allows the administrator to initialize each LUN. The

initialization process erases the first few blocks of the selected LUN to
remove any stale file system information.

6.10.1 Via Web Interface

To initialize a LUN via the Web Management Interface:


• Click on the “Management Control Processor” graphic.

• Click on the “LUN Config” tab.

• Select the LUN to edit by clicking on the LUN graphic.

• Click the “Modify LUN” button.

• Click the “Initialize” button.

6.10.2 Via Text Management

To initialize a LUN via the Text Management Interface:
• From the Telnet Main Menu, select “LUN Setup

• Select “Modify LUN(s)

• Select LUN (See instructions in Section 6.5 )

• Select “Initialize LUN

• Select “Exit to the LUN configuration menu

To save the changes once you have completed all LUN

configuration, select “Save changes and exit

RamSan-300/320/325 User’s Manual

- 83 -