5 control and status registers – Texas Instruments MSP430x1xx User Manual

Page 261

Advertising
background image

Control and Status Registers

13-15

USART Peripheral Interface, SPI Mode

13.5 Control and Status Registers

The USART registers, shown in Tables 13–2 and 13–3, are byte structured and
should be accessed using byte instructions.

Table 13–2.USART0 Control and Status Registers

Register

Short
Form

Register
Type

Address

Initial State

USART control

UCTL0

Read/write

070h

See Section 13.5.1

Transmit control

UTCTL0

Read/write

071h

See Section 13.5.2

Receive control

URCTL0

Read/write

072h

See Section 13.5.3

Modulation control

UMCTL0

Read/write

073h

Unchanged

Baud rate 0

UBR00

Read/write

074h

Unchanged

Baud rate 1

UBR10

Read/write

075h

Unchanged

Receive buffer

URXBUF0

Read/write

076h

Unchanged

Transmit buffer

UTXBUF0

Read

077h

Unchanged

Table 13–3.USART1 Control and Status Registers

Register

Short
Form

Register
Type

Address

Initial State

USART control

UCTL1

Read/write

078h

See Section 13.5.1

Transmit control

UTCTL1

Read/write

079h

See Section 13.5.2

Receive control

URCTL1

Read/write

07Ah

See Section 13.5.3

Modulation control

UMCTL1

Read/write

07Bh

Unchanged

Baud rate 0

UBR01

Read/write

07Ch

Unchanged

Baud rate 1

UBR11

Read/write

07Dh

Unchanged

Receive buffer

URXBUF1

Read/write

07Eh

Unchanged

Transmit buffer

UTXBUF1

Read

07Fh

Unchanged

All bits are random following the PUC signal, unless otherwise noted by the
detailed functional description.

Reset of the USART module is performed by the PUC signal or a SWRST. After
a PUC signal, the SWRST bit remains set and the USART module remains in
the reset condition. It is disabled by resetting the SWRST bit. The SPI mode
is disabled after the PUC signal.

The USART module operates in asynchronous or synchronous mode as
defined by the SYNC bit. The bits in the control registers can have different
functions in the two modes. All bits are described with their function in the
synchronous mode—SYNC = 1. Their function in the asynchronous mode is
described in Chapter 12.

Advertising