14.4.6 Measuring the Offset Voltage of Comparator_A

The input offset voltage of the comparator varies with each device and also
with temperature, supply voltage, and input voltage. If the input voltage is
stable (

reference voltage), it will not influence the offset voltage significantly.

To increase the precision of voltage measurements, the comparator offset
voltage can be measured by the following steps. To simply compensate for the
offset without measuring it, see section 14.4.7

First, execute a conversion with CAEX = 0. V

CA0

is applied to the + terminal

of the comparator, and V

ref

is applied to the – terminal of the comparator as

shown in Figure 14–18.

Figure 14–18. Measuring the Offset Voltage of the Comparator, CAEX = 0

_

+

0

1

CAF

Set

CAIFG

τ

2

µ

s

0

1

0

1

0

1

0

1

CA0

CA1

0

1

P2CA0

P2CA1

CAEX

Vref

CAON

VCC

0 V

1

0

e.g.
Capture
Input of
Timer_A

CAOUT to
External Pin

The V

offset

in this configuration is in series with V

ref

as shown in Figure 14–19.

V

CA0

=

V

ref

+

V

offset

Figure 14–19. Offset Voltage of the Comparator, CAEX = 0

_

+

0

1

CAF

Set

CAIFG

τ

2

µ

s

0

1

CAEX

Voffset

VCA0

Vref

CAON

VCC

0 V

1

0

e.g.
Capture
Input of
Timer_A

CAOUT to
External Pin

Next, execute a conversion with CAEX = 1. V

CA0

is applied to the – terminal

of the comparator, and V

ref

is applied to the + terminal of the comparator as

shown in Figure 14–20.

Advertising