12TECHNICAL DATA

Standard:

DECT (Digital Enhanced Cordless Telecommunications)
GAP (Generic Access Profile)

Frequency range:

1880 MHZ to 1900 MHz

Number of channels:

120 duplex channels

Modulation:

GFSK

Speech coding:

32 kbit/s

Emission power:

10 mW (average power per channel)

Range:

300 m in open space /50 m maximum inhouse

Numbr of handsets:

Up to 5

Powersupply base

230V / 50 Hz / 35 mA 6,5V DC 180mA & 150mA

Handset Batteries:

2 rechargeable batteries AAA, NiMh 750mAh 1,2V

Handset autonomy:

100 hours in standby

Talk time:

10 hours

Charging time:

6-8 hours

Normal conditions of use:

+5 °C to +45 °C

Flash time

100 or 250 ms

13DEFAULT SETTINGS

Handset name:

OG-R400

Auto talk:

ON

PABX code

Empty (Off)

Handset ring volume:

3

Ear volume:

3

Melody Handset:

Internal calls = 1 and external = 5

Menu color:

Blue

Base ring volume:

3

Base ringtone:

1

Pin code:

0000

Key lock:

Off

SMS melody:

On = Morse

The icon

flashes

Handset out of range

Bring the handset closer to
the base

The base has no power sup-
ply

Check the mains connection
to the base

The handset is not registered
on the base

Register the handset on the
base

Base or handset do not ring

The ringing volume is zero or
low

Adjust the ringing volume

Not possible to transfer a call
on PABX

The FLASH time is too short Set the unit to Long Flash

time

Telephone does not react to
pressing the keys

Manipulation error

Remove the batteries and put
them back in place