2head - synchronous data compression (sdc) testing, Synchronous data compression (sdc) testing – Telenetics V.34-SDC User Manual

Page 115

Advertising
background image

Troubleshooting Guide 6-11

T

roub

leshooting

Initiating and Terminating Tests from the Modem’s Front Panel

To initiate a test from the modem’s front panel:

1) Press

until

you

reach

the

TEST

OPTS

category.

2) Press

until

you

reach

Test=End Test.

3) Press

until

Test=LAL (for example)

4) Press

to

start

the

test.

To terminate a test from the modem’s front panel:

1) Press

until

Test=End Test.

2) Press

to

stop

the

test.

Synchronous Data Compression (SDC) Testing

When performing diagnostic tests in SDC mode, note the following:

• All tests are supported

• When initiating the following “online” tests:

— Remote digital loopback

— Remote digital loopback pattern

— Data mode pattern

— Local digital loopback

during SDC connection, the modem falls back to Direct mode (Mode=Direct,
AT

*

SM) to run the test. If the modem is set for internal timing

(Clock=Internal, AT&X) the DTE clock is changed to match the DCE rate. If
the modem is set for external timing (Clock=External, AT&X), the clock rate
provided may not match the DCE rate and the test will not function. (Set
Clock=Internal temporarily to complete testing, and then reset to External.)

• To test the synchronous data path’s integrity while running loopback tests, set

the modem for one of the asynchronous buffered modes (Mode=Normal,
Reliable, Auto Reliable, or Speed Auto Reliable).