179

TANDBERG Audio Science microphone elements: Audio Technica AT-861PZ and Crown PZM-
6D

Signal levels -
microphone
inputs

Clipping level

Nominal level

Input menu level
settings

Vpp

dBu

dBu

0.0 dB

83.0 mVpp

-28.4 dBu

-46.4 dBu

1.5 dB

69.8 mVpp

-29.9 dBu

-47.9 dBu

3.0 dB

58.8 mVpp

-31.4 dBu

-49.4 dBu

4.5 dB

49.4 mVpp

-32.9 dBu

-50.9 dBu

6.0 dB

41.6 mVpp

-34.4 dBu

-52.4 dBu

7.5 dB

35.0 mVpp

-35.9 dBu

-53.9 dBu

9.0 dB

29.4 mVpp

-37.4 dBu

-55.4 dBu