3 network, Network – TANDBERG MXP User Manual

Page 236

Advertising
background image

TANDBERG Maestro MXP

236


Audio output connector specification:

Connector label

Audio outputs

Signal type

Unbalanced

Connector (codec)

Female RCA/phono, sleeve-ground,
centre-signal

Output impedance

680 ohms

Max output level when set
to maximum output level
and volume control set to
max.
Max output level when set
to minimum output level and
volume control set to max.

15.5 Vpp

1.2 Vpp

Range, menu adjustable
output gain

22.5 dB (16 steps of 1.5 dB)*

Volume control attenuation
(audio out 1)

0 to 21 dB + mute (steps of 1.5 dB)


* Additional attenuation is possible on room/loudspeaker audio output using the volume control
setting

5.1.3 Network

Ethernet:
1 x Ethernet (RJ-45 Jack) LAN interface (10/100 Mb) up to 4 or 6 Mbps depending on the
bandwidth option installed.

To connect the system to a LAN, use the Ethernet cable provided by TANDBERG (or a standard
Ethernet cable).

The cable specification is:

1 ------------ 1
2 ------------ 2
3 ------------ 3
6 ------------ 6

If no LAN is available and the codec is connected directly to a computer, use a crossover cable.

The crossover cable specification is:


If such a connection is needed, the system and the PC must use ‘static’ TCP/IP settings because
no DHCP server is controlling the small “LAN”, which has been created between the computer
and the system. When configuring a back-to-back connection between the PC and the system,
make sure both static IP addresses exist on the same subnet.