Implementation Details

5-61

Code Development Tools

;–––––––––––––––––––––––––––––––––––––––––––––––––––––
; called from C––
; void oport(char Port, int Data)
; Writes Data to the I/O port specified by the letter Port.
; Example:
; oport(’B’, 0xAA); //Write 0xAA to port B.
;–––––––––––––––––––––––––––––––––––––––––––––––––––––
_oport
mov

a0, *r7 – 4

; port address

mov

a0~, *r7 – 2

; data

add

a0, _out_port_access – ’A’ ; find the location in the table

mov

a0, *a0

; get the value of the label in the table

jmp

*a0

; jump to the label from the table

_prta

out

0x00, a0~

; write to PortA

ret

_prtb

out

0x08, a0~;

write to PortB

ret

_prtc

out

0x10, a0~

; write to PortC

ret

_prtd

out

0x18, a0~

; write to PortD

ret

_prte

out

0x20, a0~

; write to PortE

ret

_out_port_access

; table for table lookup

DATA

_prta

DATA

_prtb

DATA

_prtc

DATA

_prtd

DATA

_prte

;–––––––––––––––––––––––––––––––––––––––––––––––––––––
;–––––––––––––––––––––––––––––––––––––––––––––––––––––
; called from C––
; int iport(char Port)
; Reads data from the I/O port specified by the letter Port.
; Example:
; int data = iport(’F’); //Read port F.
;–––––––––––––––––––––––––––––––––––––––––––––––––––––
_iport
mov

a0, *r7 – 2

; port address

add

a0, _in_port_access – ’A’ ; find the location in the table

mov

a0, *a0

; get the value of the label in the table

jmp

*a0

; jump to the label from the table

_iprta

in

a0, 0x00

; read from PortA

ret

_iprtb

in

a0, 0x08

; read from PortB

ret