4 interrupt/general control register – Texas Instruments MSP50C614 User Manual

Page 87

Advertising
background image

Interrupt/General Control Register

3-17

Peripheral Functions

3.4

Interrupt/General Control Register

The interrupt/general control (IntGenCtrl) is a 16-bit wide port-mapped register
located at address 0x38. The primary component in the IntGenCtrl is the 8-bit
interrupt mask register (IMR). The service branch enable status for each of the
eight interrupts is registered in the IMR. A SET bit in the IMR enables that
interrupt to assume the service branch (at the time that the associated trigger
event occurs). A CLEAR bit disables the service branch for that interrupt. The
IMR is located at bits 0 through 7 in the IntGenCtrl. Bit 0 is associated with
INT0, which is the highest priority interrupt. Bit 7 is associated with INT7. Refer
to Section 2.7,

Interrupt Logic, for more information regarding the

interrupt-system logic and initialization sequence.

IntGenCtrl register

address 0x38

(16-bit wide location)

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

CE

AR

PD

EP

E2

E1

S2

S1

D5

D4

PF D3

D2

T2

T1

DA

low
priority

high

priority

0x0000 : State after RESET low

Interrupt mask register

CE : Comparator enable
AR : ARM bit
PD : Pulse-density clock: PDMCD
EP : Enable pullup resistors on port F

D5 : port D

5

falling-edge

D4 : port D

4

rising-edge

D3 : port D

3

falling-edge

D2 : port D

2

rising-edge

E2 : Enable TIMER2 (1 value starts timer)
E1 : Enable TIMER 1 (1 value starts timer)
S2 : Clock source for TIMER2 (0 chooses 1/2 MC)
S1 : Clock source for TIMER1 (0 chooses 1/2 MC)

PF : any port F falling-edge
T2 : TIMER2 underflow
T1 : TIMER1 underflow
DA : DAC timer underflow

(1 value enables interrupt service)

The remaining bits in the IntGenCtrl have various control functions which are
not directly related to the interrupt system. Four of these are related to the timer
functions. Bits 8 and 9 are used to select the clock sources which govern the
rates of TIMER1 and TIMER2. Clearing bit 8 chooses 1/2 MC as the source
for TIMER1 (i.e., the TIMER runs at one-half the frequency of the Master
Clock). Setting bit 8 chooses the oscillator reference (RTO or CRO) as the
source for TIMER1. (The same applies for bit 9 and TIMER2.) Bits 10 and 11
in the IntGenCtrl are used to enable TIMER1 and TIMER2, respectively.
Setting bit 10

starts TIMER1, and clearing bit 10 stops TIMER1. (The same

applies for bit 11 and TIMER2).