3. Installation of the EX-16 System

3.1 Precautions for Installation

3.1.1 Exchange

Pay particular attention to the following points:

* The layout should allow easy servicing and inspection.

* The exchange is compact and lightweight; however, it is important to

ascertain the strength of the wall on which it will be placed.

* The exchange should be grounded. When it is used in combination with

other systems (for example, with a PA system) the exchange should

be connected to the other components for common grounding.

* Choose a low "source noise" AC power supply for the exchange. Line

noise can affect speech quality.

* Make sure that the AC power circuit provides adequate insulation and

capacity.

This high-performance exchange is compact as well as quiet, and can be

easily installed almost anywhere. Areas described below, however, should

be strictly avoided.

* An area where it will obstruct traffic, for example, in a hallway or near

the entrance or exit of a room.

* An area where it will be exposed to fire, heat or direct sunlight. Suitable

ambient temperature is +32°~104°F (0°~40°C).

* A dusty area where it will be exposed to metal dust or dirt.

* Near a storage place for chemicals, oil, etc.

* An area subject to vibration.

* Near high-voltage equipment.

* In a strong electrical field.

* Near

equipment vulnerable to the influence of an electrical field.