3.2 Cable Installation

Wire type, number of wire pairs and number of individual wires are to be

determined for individual sections of the wiring system according to the

guidelines set down below.

* 4-wire twisted pair cables are to be used for wiring between indoor

terminal boards, intermediate terminal boards, main terminal boards, etc.

* Outdoor wires should be used where wiring passes through inaccessible

areas such as in ceilings or under floors. Indoor wires may also be used,

however, in cases where there is no risk of deterioration due to exposure

to heat, etc.

* The number of cable pairs laid should be determined considering the

possibility of future expansion of the system.

* There is a limit to the diameter of cables that can be used to connect

stations to the terminals of EX-16. This limit must be taken into con-

sideration when planning the wiring of this system. The diameter should

measure between 0.016" (0.41mm) and 0.031" (0.79mm).

3.3 Core Diameter Versus Transmission Distance

The diameter of the cable to be used should be determined so that the set

limits for speech attenuation (3dB maximum for transmission from the

exchange to the station) and for the DC resistance (DC loop resistance: less

than 300 ohms) are met.

Speech Attenuation, DC Loop Resistance and Service

Distance as Functions of Core Diameter

AWG no.

(solid)

22

24

Core

Diameter

mils. (mm)

25.3

(0.64)

20.1

(0.51)

Speech

Attenuation

dB per 1000 ft.

(dB per 1 km)

0.411

(1.35)

0.521

(1.71)

DC Loop

Resistance

per 1000 ft.

per 1 km)

35.1

(115)

54.5

(179)

Service

Distance

ft.

(km)

7,300

(2.2)

5,500

(1.1)

12