5.2 Fault in Specific Station Only

Find the cause according to the following table if the fault lies with a specific

station only, not with all stations.

SYMPTOM

Dialing can not be
made at privacy off
mode.

Specific key does not
operate.

Calling tone can
not be heard.
Sound from the

other party can not

be heard.

Sound is not trans-
mitted to the other

party.

On dialing, noise is
heard by the called
party.

Sound of the other
party is broken during
call.

Immediately after the

calling tone, the line
switches to cancel,
busy, dial tone, etc.

CHECK-ITEM

Replace the

station and make
sure that the

station is not
faulty.

Replace the
station and make

sure that the
station is not
faulty.

Same symptom
remains even if

the station is

replaced.
Becomes normal
if the station is
replaced.

Same symptom
remains even if
the station is

replaced.
Becomes normal
if the station is
replaced.

Same symptom
remains even if
the station is
replaced.
Becomes normal
if the station is
replaced.

Same symptom
remains even if
the station is
replaced.

Same symptom
remains even if
the station is
replaced.
Becomes normal
if the station is
replaced.

CAUSE

* Disconnection of both T & R Lines.
* T & R Lines are shorted.

* Fault in key board switch or matrix circuitry.
* Fault in the dial generator. (Replace PCB

board.)

* Short or open in R Line.
* Fault in LAU.

* Disconnection of R Line or improper connec-

tion of the station connector.

* Fault in LAU.
* Station fault.

* Short or open in T Line.
* Fault in LAU.

* Fault in MIC circuitry of the station. (Replace

MIC or PCB.)

* One of T Lines is disconnected.
* Fault in LAU.

* Fault in MIC element.
* Fault in T Line of the station.
* Low-frequency oscillation of MIC AMP.

(Faulty bypass capacitor.)

* Adjust the volume control of station speaker

if the room produces reverberation. (Lower
the volume.)

* Increase the gain of MIC AMP.
* Replace PCB after checking if MIC unit is not

touching its case.

* One of R Lines is disconnected.
* Fault in LAU.
* Station fault.

* One of the R Lines is disconnected or the

station connector is not connected properly.