Perreaux SILHOUETTE SXV1 User Manual

Page 13

Advertising
background image

13

Capacitance

Loading

Table

Use this table to match the capacitance loading characteristics of
your SXV1 to that recommended by your cartridge manufacturer,
where switch in UP position is OFF and switch in DOWN
position is ON. Consult your cartridge documentation for the
correct capacitance figure.

C Load

Dip Switch Setting

(pF)

6

7

8

9

27

UP

UP

UP

UP

54

DOWN

UP

UP

UP

74

UP

DOWN

UP

UP

101

DOWN

DOWN

UP

UP

297

UP

UP

DOWN

UP

324

DOWN

UP

DOWN

UP

344

UP

DOWN

DOWN

UP

371

DOWN

DOWN

DOWN

UP

417

UP

UP

UP

DOWN

444

DOWN

UP

UP

DOWN

464

UP

DOWN

UP

DOWN

491

DOWN

DOWN

UP

DOWN

687

UP

UP

DOWN

DOWN

714

DOWN

UP

DOWN

DOWN

734

UP

DOWN

DOWN

DOWN

761

DOWN

DOWN

DOWN

DOWN

Gain Setting

Table

Use this table to configure the gain characteristics of your SXV1
to suit the output voltage of the cartridge you are using, where
switch in UP position is OFF and switch in DOWN position is
ON.

Consult your cartridge documentation for it’s rated output
voltage. Set the gain configuration where the “Sensitivity” of
your SXV1 is within ±25% of your cartridge output voltage. If
no configuration falls into this bracket, use the setting with the
sensitivity higher than your cartridge output voltage.

Gain

Sensitivity S/N Ratio THD+N

Dip Switch Setting

(dB)

(mV)

(dB)

(%)

10

11

12

40

7.57

81.9

0.010

UP

UP

UP

50

2.36

74.6

0.022 DOWN

UP

UP

59

0.81

64.0

0.058

UP

DOWN

UP

61

0.66

62.6

0.067 DOWN

DOWN

UP

70

0.23

55.4

0.122

UP

UP

DOWN

71

0.22

55.1

0.188 DOWN

UP

DOWN

72

0.18

54.6

0.199

UP

DOWN

DOWN

73

0.17

53.4

0.203 DOWN

DOWN

DOWN

Advertising