Perreaux SILHOUETTE SXV1 User Manual

Page 14

Advertising
background image

14

Note: If more than one setting falls within ±25% of your cartridge

output voltage, the lower sensitivity configuration will

result in greater dynamic range, the higher will be less

susceptible to clipping.

Note: Rated output is 0.75V

RMS

.

Sensitivity value measured at rated output.
Gain measured at 1kHz.

Configuration

Example

Please use the following example of the popular Ortofon
Kontrapunkt b (Moving Coil) cartridge as a guideline.

Ortofon Kontrapunkt b specifications

Recommended load resistance:

50

-200

Recommended load capacitance:

not stated

Rated output voltage:

470µV

SXV1 configuration

Resistance loading:

89.7

Capacitance loading:

27pF

(if no capacitance loading is recommended, use the lowest value)

Gain:

61dB

(based on Sensitivity bracket of 470ìV±25%

⇒ 352.5µV-587.5µV)

DIP Switch Setting (left channel)

1 2 3 4 5 6 7 8 9 10 11 12

D D D D U U U U U D D U

Note: D = switch in DOWN position, U = switch in UP position

Note: The right and left DIP switches are a mirror image of each

other.