Table PD-2 — Gross Cooling Capacities (MBh)

12½ Ton Horizontal Three Phase

WCH150B

Ambient Temperature (F)

85

95

105

115

Enter.
Dry

Entering Wet Bulb (F)

CFM

Bulb

61

67

73

61

67

73

61

67

73

61

67

73

Airflow

(F)

MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC

75

140.0 113.0 153.0 91.1 159.0 58.0 128.0 106.0 149.0 83.3 160.0 56.2 116.0 100.0 137.0 82.9 157.0 53.5 104.0 93.5 124.0 76.7 147.0 48.9

4500

80

141.0 134.0 154.0 105.0 160.0 78.3 130.0 128.0 149.0 104.0 161.0 77.5 119.0 119.0 138.0 98.4 157.0 74.3 109.0 109.0 124.0 91.9 148.0 69.6

85

146.0 146.0 155.0 124.0 161.0 94.3 139.0 139.0 149.0 125.0 162.0 96.0 129.0 129.0 138.0 119.0 158.0 95.0 119.0 119.0 125.0 113.0 148.0 90.2

90

153.0 153.0 156.0 143.0 163.0 110.0 148.0 148.0 151.0 145.0 163.0 114.0 140.0 140.0 139.0 139.0 158.0 115.0 130.0 130.0 129.0 129.0 148.0 111.0

75

143.0 119.0 154.0 93.3 160.0 59.0 132.0 113.0 151.0 86.8 161.0 57.4 119.0 106.0 141.0 88.2 159.0 54.7 107.0 99.8 127.0 81.8 151.0 50.8

5000

80

145.0 142.0 156.0 109.0 162.0 79.9 134.0 134.0 152.0 109.0 162.0 79.6 124.0 124.0 141.0 104.0 159.0 77.3 114.0 114.0 128.0 97.7 151.0 72.9

85

150.0 150.0 157.0 129.0 164.0 96.6 145.0 145.0 152.0 131.0 164.0 98.7 135.0 135.0 142.0 127.0 160.0 99.1 125.0 125.0 129.0 121.0 151.0 95.5

90

156.0 156.0 158.0 149.0 164.0 112.0 153.0 153.0 153.0 153.0 165.0 118.0 146.0 146.0 146.0 146.0 161.0 120.0 136.0 136.0 136.0 136.0 151.0 118.0

75

145.0 124.0 156.0 95.9 160.0 60.1 135.0 119.0 153.0 90.8 162.0 58.5 122.0 112.0 144.0 93.2 160.0 55.8 110.0 106.0 130.0 86.9 153.0 52.3

5500

80

147.0 147.0 157.0 111.0 162.0 80.8 139.0 139.0 154.0 114.0 163.0 81.0 129.0 129.0 144.0 110.0 161.0 80.1 118.0 118.0 130.0 103.0 154.0 76.0

85

154.0 154.0 158.0 133.0 164.0 97.9 149.0 149.0 155.0 137.0 165.0 101.0 140.0 140.0 145.0 135.0 162.0 103.0 130.0 130.0 132.0 128.0 154.0 100.0

90

159.0 159.0 160.0 153.0 166.0 115.0 157.0 157.0 157.0 157.0 167.0 121.0 151.0 151.0 151.0 151.0 163.0 125.0 141.0 141.0 141.0 141.0 154.0 124.0

75

147.0 129.0 157.0 98.2 161.0 60.6 138.0 125.0 155.0 92.9 163.0 59.5 125.0 118.0 146.0 88.7 161.0 57.1 111.0 111.0 132.0 91.8 155.0 52.5

6000

80

150.0 150.0 158.0 114.0 163.0 81.5 144.0 144.0 156.0 118.0 164.0 82.1 133.0 133.0 147.0 115.0 162.0 82.3 122.0 122.0 133.0 109.0 155.0 78.8

85

156.0 156.0 160.0 136.0 165.0 99.1 153.0 153.0 157.0 143.0 166.0 103.0 145.0 145.0 148.0 142.0 163.0 106.0 134.0 134.0 134.0 134.0 156.0 105.0

90

161.0 161.0 162.0 157.0 167.0 117.0 160.0 160.0 160.0 160.0 168.0 124.0 155.0 155.0 155.0 155.0 164.0 130.0 146.0 146.0 146.0 146.0 156.0 130.0

Notes:
1. Dry Coil Condition. Total Gross Cooling Capacity (MBh) shown to the left is not applicable. In this case the Sensible Heat Capacity (SHC) is the total capacity.
2. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
3. MBH = Total Gross Capacity
4. SHC = Sensible Heat Capacity

Table PD-1 — Gross Cooling Capacities (MBh)

12½ Ton Downflow Three Phase

WCD150B

Ambient Temperature (F)

85

95

105

115

Enter.
Dry

Entering Wet Bulb (F)

CFM

Bulb

61

67

73

61

67

73

61

67

73

61

67

73

Airflow

(F)

MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC

75

140.0 113.0 153.0 90.8 158.0 57.9 128.0 106.0 149.0 83.3 160.0 56.3 116.0 99.8 137.0 83.3 157.0 53.5 104.0 93.3 124.0 77.1 148.0 48.9

4500

80

141.0 134.0 154.0 105.0 159.0 78.3 130.0 128.0 149.0 104.0 161.0 77.4 119.0 119.0 138.0 98.3 157.0 74.3 109.0 109.0 125.0 91.8 148.0 69.6

85

146.0 146.0 155.0 124.0 160.0 94.3 139.0 139.0 150.0 125.0 162.0 95.8 129.0 129.0 138.0 119.0 158.0 94.9 119.0 119.0 125.0 113.0 148.0 90.2

90

153.0 153.0 156.0 143.0 162.0 111.0 148.0 148.0 151.0 145.0 163.0 114.0 140.0 140.0 139.0 139.0 158.0 114.0 130.0 130.0 129.0 129.0 148.0 111.0

75

143.0 119.0 154.0 93.5 159.0 59.0 132.0 113.0 152.0 87.2 161.0 57.4 119.0 106.0 141.0 88.6 159.0 54.8 107.0 99.5 127.0 82.3 151.0 50.9

5000

80

145.0 141.0 156.0 108.0 160.0 79.2 134.0 134.0 152.0 109.0 162.0 79.5 124.0 124.0 141.0 104.0 160.0 77.2 114.0 114.0 128.0 97.5 151.0 72.9

85

150.0 150.0 157.0 128.0 162.0 97.0 145.0 145.0 153.0 131.0 164.0 98.4 135.0 135.0 142.0 127.0 160.0 98.9 125.0 125.0 129.0 120.0 152.0 95.3

90

156.0 156.0 158.0 148.0 164.0 112.0 153.0 153.0 155.0 153.0 165.0 118.0 146.0 146.0 146.0 146.0 161.0 120.0 136.0 136.0 136.0 136.0 152.0 118.0

75

145.0 124.0 155.0 96.1 160.0 60.0 135.0 119.0 153.0 90.7 162.0 58.5 122.0 112.0 144.0 93.8 160.0 55.7 110.0 105.0 130.0 87.4 154.0 52.4

5500

80

147.0 147.0 157.0 111.0 162.0 80.5 139.0 139.0 154.0 113.0 163.0 80.9 129.0 129.0 144.0 110.0 161.0 79.9 118.0 118.0 131.0 103.0 154.0 75.9

85

153.0 153.0 158.0 132.0 164.0 97.4 149.0 149.0 155.0 137.0 165.0 101.0 140.0 140.0 145.0 134.0 162.0 102.0 130.0 130.0 132.0 128.0 154.0 100.0

90

159.0 159.0 160.0 152.0 166.0 115.0 157.0 157.0 157.0 157.0 166.0 121.0 151.0 151.0 151.0 151.0 163.0 125.0 141.0 141.0 141.0 141.0 154.0 124.0

75

147.0 128.0 156.0 98.4 160.0 60.0 138.0 125.0 155.0 92.7 163.0 59.5 125.0 118.0 147.0 88.6 161.0 57.2 112.0 111.0 132.0 92.4 155.0 52.5

6000

80

150.0 150.0 158.0 113.0 162.0 81.2 144.0 144.0 156.0 117.0 164.0 82.1 133.0 133.0 147.0 115.0 162.0 82.1 122.0 122.0 133.0 108.0 156.0 78.7

85

156.0 156.0 159.0 135.0 164.0 98.4 153.0 153.0 157.0 142.0 166.0 103.0 145.0 145.0 148.0 141.0 163.0 106.0 134.0 134.0 134.0 134.0 156.0 104.0

90

160.0 160.0 161.0 156.0 166.0 116.0 160.0 160.0 160.0 160.0 167.0 123.0 155.0 155.0 155.0 155.0 165.0 129.0 146.0 146.0 146.0 146.0 157.0 130.0

Notes:
1. Dry Coil Condition. Total Gross Cooling Capacity (MBh) shown to the left is not applicable. In this case the Sensible Heat Capacity (SHC) is the total capacity.
2. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
3. MBH = Total Gross Capacity
4. SHC = Sensible Heat Capacity