Fault code troubleshooting – TurboChef Technologies 2020 User Manual

Page 47

Advertising
background image

2 7

TR
OUBLESHOO

TING

Fault Code Troubleshooting

From

TEST MODE

, you can test separate oven components to help diagnose an issue. To access

TEST

MODE

, see page 17.

Troubleshooting:

F1:BLOWER FAULT

Access the

TEST MODE

.

(page 17)
Are the status indicators at
location 7 and 8 present
(page 18)?

NO

YES

7

8

Open Left End
Bell.

Is a fault code
present on the
BMSC?

Open the Right
End Bell.

Is a fault code
present on the
BMSC?

See page 28.

YES

YES

NO

NO

Is the wiring connected properly?

Check the BMSC, blower motor,
and I/O control board (see page
28).

Correct wiring
or replace I/O
control board,
BMSC, or
blower motor
if damaged
(page A-6 =
lower, A-8 =
upper).

Check the I/O control
board, BMSC, and blower
motor wiring (pages 37-38).

Is the blower motor
spinning freely?

NO

Remove obstruction or, if
necessary, replace blower
motor (page A-6 = lower,
A-8 = upper).

YES

Do resistance measurements
between windings and
chassis agree with values on
motor windings resistance
table (Figure 36)?

YES

See page 28.

NO

Replace the
blower motor
(page A-6 =
lower, A-8 =
upper).

To

From

Description

Expected Resistance

Black

Red

Winding (A-B)

2.3-2.8

W

Black

White

Winding (A-C)

2.3-2.8

W

Red

White

Winding (B-C)

2.3-2.8

W

N/A

Green

Windings to chassis

Open

Figure 36: Motor Windings Resistance Table

NO

YES