Troubleshooting:

F9: BELT FAULT (Total Belt Run Failure)

Are there any obstructions that
are blocking the conveyor’s
movement or is the conveyor
belt damaged?

Remove obstruction or
replace/repair the conveyor and
restart the oven. Is the F9 fault
code still present?

YES

Remove the chain guard
(page A-4).
Is the chain damaged or
obstructed in any way?

NO

YES

Remove obstruction
or, if necessary,
replace the chain.

YES

NO

Open the right end bell (also open the
left end bell if split belt conveyor). Is the
wiring correct from the conveyor motor
to the conveyor motor controller to the
control board correct (pages 37-40)?

NO

Correct wiring (pages
37-40).

Is the conveyor motor, CMSC, or
I/O control board damaged or
defective? (See Figure 37 for
motor winding resistance.)

YES

To

From

Description

Expected Resistance

White

Gray

Winding (A-B)

215-217

W

White

Black

Winding (A-C)

215-217

W

Gray

Black

Winding (B-C)

215-217

W

White, Gray, or Black Chassis

Windings to chassis

Open

Figure 37: Motor Ohm Chart (Motor Windings, not Hall Effect Sensor)

NO

Check that the CMSC
settings correctly
correspond with
TurboChef settings
(page 24 and 40).

YES

Replace parts as
required (see
appendix).