Troubleshooting:

F2: LOW COOK TEMP

Restart the oven, access the

TEST MODE

, and turn on

both the top and bottom blowers. Are the status indi-
cators at location 6, 7, 8, and 9 present (pages 18-19)?

Open the right end bell.

NO

Fix wiring/connections.

Is wire harness properly
connected?

NO

Fix connection.

Test the RTD (page 22
for resistance/
temperature chart).

Is the RTD damaged
or defective (page 22)?

NO

Replace the I/O control
board (page A-8).

YES

Troubleshoot the
blowers (pages
27-28).

NO

YES

YES

Is the RTD properly connect-
ed to the I/O control board
(page 37-40)?

YES

Are the nozzles and plenums
correctly installed?

NO

Correctly reinstall the
nozzles and plenums.

YES

NO

Replace element(s).

Are all elements heating
(ensure amp draw is correct -
page 24)?