TurboChef Technologies 2020 User Manual

Page 52

Advertising
background image

3 2

T R O U B L E S H O OT I N G

Troubleshooting:

F8: HIGH LIMIT TRIPPED

Is the high limit thermostat
tripped (page 21)?

Reset and determine why it
tripped - over temp, blower
failure, etc.

Check if the high limit probe
or RTD is damaged or defec-
tive, replace if needed (page
A-8).

NO

YES

Troubleshooting:

F7: RTD FAULT

Open the right end bell.

Is the RTD damaged or
defective (page 22)?

Is the RTD
connected
properly to the
I/O control
board
(pages 37-40)?

Replace the I/O
control board
(page A-8).

NO

Correct wiring
(pages 37-40).

Replace the RTD
(page A-8).

YES

NO

NO

YES

Are all the contacts
closed on the high
limit thermostat?

Is the wiring
correct (pages
37-40)?

NO

YES

Replace the high
limit thermostat
(page A-6).

NO

YES

Correct wiring
(pages 37-40).

Replace the I/O
control board
(page A-8).

Is the RTD open? Using an ohmmeter,
measure at the control board (pages 37-
40). RTD should measure
approximately 100

W at 32°F (0°C) See

page 22 for ohm/temperature chart.

YES

Advertising