Typical wiring diagrams, Babs – Thomas & Betts RGM 405 User Manual

Page 17

Advertising
background image

Mfg No. 164771, Page 17

TYPICAL WIRING DIAGRAMS

Figure 17 - Typical Wiring Diagram for Model CAUA with Direct-Drive Blower Motor(s)

208 OR 230/1/60

GRD

G

BK

OPTIONAL DISCONNECT SWITCH

CONTACTS

HEAT SPEED

W

MOTOR

BLOWER

L1

L2

PROTECTED

INHERENTLY

COOL SPEED CONTACTS

BL

BK

W

BL

W

BK

BK

W

INHERENTLY

PROTECTED

BLOWER

MOTOR

G

GRD

BL

BL

BK

BK

W

W

W

W

BK

BK

W

W

VENTER MOTOR

40 VA. CONTROL

BK

BL

24V

LINE VOLT

BR

TRANSFORMER

Y

CMB

ACB HEAT

LINE

GROUND

VALVE

PSW

HI LIMIT

HI LIMIT

PRESSURE SWITCH

HIGH

LIMIT

W

G

R

24VAC

DSI CONTROL

FLAME SENSING

PROBE

FLAME SENSE

IGNITOR

HV LEAD

LED CODES

SLOW FLASH NORMAL OPERATION - NO CALL FOR HEAT

FAST FLASH NORMAL OPERATION - CALL FOR HEAT

2 FLASHES SYSTEM LOCKOUT - FAILED TO DETECT OR SUSTAIN FLAME

3 FLASHES PRESSURE SWITCH OPEN OR CLOSED

4 FLASHES HIGH LIMIT OPEN

5 FLASHES FLAME SENSED AND GAS VALVE NOT ENERGIZED

STEADY ON INTERNAL FAILURE (MICRO-CONTROLLER FAILURE: SELF CHECK)

FIELD CONTROL WIRING

150'

250'

350'

75'

125'

175'

#18 GA. WIRE

#16 GA. WIRE

#14 GA. WIRE

TOTAL WIRE

LENGTH

DISTANCE FROM

UNIT TO CONTROL

MIN. RECOMMENDED

WIRE GUAGE

ROLLOUT

LED

BK

BK

BL

BL

BL

BL

R

Y

Y

R

BR

BK OR BR

BK

BK OR BL

BR

R

FIELD WIRING

OPTIONAL FACTORY WIRING

FACTORY WIRING

WHITE - W

PURPLE - PR

BLUE - BL

GREEN - G

YELLOW - Y

ORANGE - O

RED - R

BROWN - BR

BLACK - BK

WIRING CODE

BR

R

CHASSIS GRND.

BURNER GROUND

IN

OUT

VAC HOT

HOT

IN

BLWR AUX

L2

L2

L2

L1

L1

1

1

1

7

7

7

7

Y

2

2

C NO

NC

FLAME

ROLLOUT SWITCH

Y

CONTACTOR COIL

W

BK

ACB COOL

COOL SPEED

HEAT SPEED

CONTACTOR COIL

MAIN TERMINAL BLOCK

UNIT TERMINAL STRIP

THERMOSTAT TERMINAL STRIP

BR

Y

3

DOOR SWITCH

BL

BL

BL

Y1

Y2

W1

W2

SET ANTICIP

AT

OR A

T 0.6 AMPS

T87F THERMOST

AT

Q539A SUBBASE

W

Y

R

G

C

R

G

Y

BK

R

BL

R

BK

Y

BL

TERMINAL STRIP

THERMOSTAT

R

C

COOL RELAY COIL

CUSTOMER'S

MOTOR WIRE COLORS
WHITE - NEUTRAL

BLACK - HIGH SPEED

BLUE - MEDIUM SPEED

RED - LOW SPEED

R

R

(SEE NOTE #7)

(SEE NOTE #8)

W

(DO NOT USE WITH 208V)

(SEE NOTE)

BR

BL

BK

AL

TERNA

TE W

.R. OR ROBER

TSHA

W

BY-P

ASS GAS V

A

LV

E

PLUG PILOT OUTLET

P

MAIN

BL

PILOT

M

BR

C

OR PV

TH-TR

TH OR

BK

BY-P

ASS GAS V

A

LV

E

HONEYWELL

PILOT

MV

PLUG PILOT OUTLET

MAIN

TR OR

PV-MV

AG1 - AK2 OR AK3 - CL10 - DIRECT DRIVE

BABS

CAUA SERIES 150 - 400 DWG. # B-164607 REV #1

OPERATING SEQUENCE

1. SET THERMOSTAT SYSTEM SWITCH AT "OFF" POSITION, FAN SWITCH AT "AUTO" POSITION.

2. TURN ON MANUAL GAS VALVE.

3. TURN ON POWER TO UNIT.

5. THERMOSTAT CALLS FOR HEAT, ENERGIZING THE VENTER MOTOR.

6. VENTER PRESSURE SWITCH CLOSES, FIRING UNIT.

7. BURNER FLAME IS SENSED, AND IN 30 SECONDS THE BLOWER MOTOR IS ENERGIZED.

8. IF THE FLAME IS EXTINGUISHED DURING MAIN BURNER OPERATION, THE INTEGRATED CONTROL SYSTEM

CLOSES THE MAIN VALVE AND MUST BE RESET BY INTERRUPTING POWER TO THE CONTROL CIRCUIT

(SEE LIGHTING INSTRUCTIONS).

NOTES

1. THE FOLLOWING CONTROLS ARE FIELD INSTALLED OPTIONS: THERMOSTAT

2. DOTTED WIRING AND COOL RELAY COIL INSTALLED BY OTHERS.

3. CAUTION: IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THE

APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL

HAVING A TEMPERATURE RATING OF AT LEAST 105° C. EXCEPT FOR SENSOR

LEAD WIRE WHICH MUST BE 150° C.

4. USE 18 GA. WIRE FOR CONTROL WIRING ON THE UNIT.

6. LINE AND FAN MOTOR BRANCH WIRE SIZES SHOULD BE OF A SIZE TO PREVENT

VOLTAGE DROPS BEYOND 5% OF SUPPLY LINE VOLTAGE.

5. USE 14 GA. WIRE FOR LINE AND MOTOR WIRING ON UNIT.

4. SET THERMOSTAT SYSTEM SWITCH AT "HEAT" POSITION; FAN SWITCH AT "AUTO" POSITION.

9. SET THERMOSTAT SYSTEM SWITCH AT "COOL" POSITION, FAN SWITCH AT "AUTO" POSITION.

(A) ON A CALL FOR COOLING, BLOWER MOTOR IS ENERGIZED AT HIGH SPEED AND COOLING

CIRCUIT IS ENERGIZED.

11. SET THERMOSTAT SYSTEM SWITCH AT "OFF" POSITION, FAN SWITCH AT "AUTO" POSITION, FOR SHUTDOWN..

10. WHEN BLOWER DOOR IS OPENED, THE UNIT IS SHUTDOWN.

7. SECOND BLOWER MOTOR ON 250-400 UNITS ONLY.

8. VENTER MOTOR ON 350-400 UNITS HAS BROWN AND BLUE WIRES.

9. ON 208/230V. UNITS THE CONTROL TRANSFORMER HAS A DUAL VOLTAGE PRIMARY.

FOR 208V. UNITS USE BLACK AND RED LEADS (CAP YELLOW)

.

FOR 230V. UNITS USE BLACK AND YELLOW LEADS (CAP RED).

10. WHEN PROVIDING OR REPLACING FUSES IN THE FUSIBLE DISCONNECT SWITCH

USE DUAL ELEMENTS TIME DELAY FUSES AND SIZE ACCORDING TO

TIMES THE MAXIMUM TOTAL INPUT AMPS.