a. Set the timer to the desired time for timed

steaming.

b. Turn the timer knob to the manual ON

position for continuous steam.

c. Let the unit stay at standby temperature.

WARNING

WHEN YOU OPEN THE DOOR, STAY AWAY FROM

STEAM COMING OUT OF THE UNIT. THE STEAM

CAN CAUSE BURNS.

4.6.9

To shut down the unit, press the ON/OFF touch

pad into the off position. The steam generator

will then drain. You may also switch off the pilot

switch to conserve energy.

4.6.10 If the HY-6G(CE) Steamer behaves as

described, the unit is functioning correctly and

ready for use.

4.6.11 Automatic Operation of Pilot

Once the pilot burner is lit, it essentially functions as a

standing pilot. In this state, if the pilot is accidentally

extinguished (by a very strong gust of wind for example),

it will re-ignite automatically. The unit will completely shut

down for a few seconds while the pilot is re-ignited.

Then the unit will come back on and resume

operation in the mode and with the (running) timer

value existing just prior to shutdown. The pilot

switch may be turned off during “off hours” to

conserve energy.

After the unit has been running, if the pilot burner

ever fails to re-ignite automatically within 90

seconds, wait 5 minutes before you attempt to

reactivate it. In the unlikely event that ignition

problems persist, contact your authorized Groen

Service Agency.

NOTE: For operation at high altitudes (2000 feet and

above) please consult the Groen Food Service

Engineering Department.

4.7 Gas Type Conversion (See Paragraph 4.3.1 for

important information for gas conversion. Verify

the type of gas to be used).

To change the type of gas used (e.g. G20 to/from

G31) change the following:

Burner injector

Pressure setting on Main Gas Valve

Data plate

Gas pressure Regulator Springs

The governor spring does not need to be changed;

only the pressure setting.

ALL CONVERSIONS

MUST BE FOR APPROVED GAS IN THE

COUNTRIES LISTED IN PARAGRAPH 4.3.1