Table 3. Local Mode Programming Instructions - Continued

Note: *Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

4. Program the next function code or exit programming mode by entering 99

on Series 500 Keyboard numeric keypad or by swiping the
Programmer's card. If using the optional 3-pos ition keyswitch, move
switch out of the AUX position.

19

MSR Send

1. While in programming mode, at the Series 500 Keyboard numeric keypad, enter

applicable Function Code 19.


LED (2) turns on.


2. At the Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1) per

list below to select MSR data from one or both good tracks.


0 = send any good track*

1 = send only if all enabled tracks good


3. Program the next function code or exit programming mode by entering 99 on Series

500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.

20 or 30

Comm (RS232)
Main Port 0 (20)
AUX Port 1 (30)
Baud Rate

1. While in programming mode, at the Series 500 keyboard numeric keypad, enter

Function Code 20 (Port 0) or 30 (Port 1).


LED (2) turns on.


2. At Series 500 Keyboard numeric keypad, enter the applicable number (1 through 9)

to select baud rate per list below.


1 = 300

6 = 9600*

2 = 600

7 = 19200

3 = 1200

8 = 38400

4 = 2400

9 = 57600

5 = 4800


LED (2) turns off.


3. Program the next function code or exit programming mode by entering 99 on Series

500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.